Ingredient Measuring Instrument - メーカー・企業と製品の一覧

Ingredient Measuring Instrumentの製品一覧

1~4 件を表示 / 全 4 件

表示件数

LP gas residue component measurement device "JLP-104"

Easy operation! A measurement device for residual components in LP gas that can be measured in a short time without requiring proficiency.

The JLP-104 is a residue component measurement device for LP gas that employs a vapor concentration method using gas chromatography, allowing for high sensitivity and automatic measurement with simple operation. The amount of LP gas required for measurement is minimal, and it can be measured in a short time without the need for specialized skills. Standard samples are measured and calibrated by injecting liquid standard oil with a microsyringe and operating in the same manner as LP gas. 【Features】 ■ Simple operation and high sensitivity ■ Fully automated operation for all processes: sample collection → concentration → GC measurement → cooling ■ Displays the current ongoing process along with a flow diagram on the touch panel ■ During adjustments, each process can be operated manually for operational confirmation ■ The analysis sample amount is approximately 10-20g per analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analysis and prediction system

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Fertilizer Component Measurement Device Auto Analyzer Type 3

You can measure the nitrogen, phosphorus, and potassium components in fertilizer ingredients (using a continuous flow analysis method).

There is a long history of use at fertilizer factories. It is ideal for process management and product management of chemical fertilizers and organic fertilizers. 【Features】 ■ Suitable for process management and product management of chemical fertilizers and organic fertilizers ■ Robust ■ Expandable ■ Excellent automation technology ■ Outstanding processing capacity and cost performance *For more details, please refer to the PDF materials or feel free to contact us.

  • Other measuring instruments
  • Other analytical equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

[Information] Nutritional Component Measurement Device 'Calorie Answer CA-Hi' Measurement Guide

A quick reference table for measurement modes is also included! Detailed explanations of the measurement principles, mechanisms, and main specifications of the products are provided.

This document is a measurement guide for the nutritional component measuring device "Calorie Answer CA-Hi." It includes an introduction to recommended measurement methods and the measurement mode creation function, as well as information on the measurement principles, mechanisms, and screening. Additionally, it presents the flow of transmission measurement for measurement cell assembly and filling, as well as reflection measurement for sample grinding. Please feel free to download and take a look. [Contents (partial)] ■ CA-Hi Features ■ Introduction to various measurement modes ■ Recommended measurement methods ■ Management and collaboration ■ Measurement mode creation function *For more details, please download the PDF or feel free to contact us.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Agricultural Soil Nutrient Measurement Device - Quattro

It is possible to measure nitrogen and phosphorus components in agricultural soil, as well as silica (using a continuous flow analysis method).

It is used at agricultural experiment stations, universities, and agricultural organizations. High-precision soil diagnostics are possible. 【Features】 ■ High precision and high sensitivity analysis based on the principle of bubble segmentation continuous flow method ■ The main console can accommodate four colorimeters ■ By adding an extra colorimeter, simultaneous analysis of up to five items is possible ■ Standard equipped with an auto sampler that can hold 120 samples ■ High-precision soil diagnostics are possible *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments
  • Other analytical equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録